Section 31 LED lighting fittings


3101. Application and general

LED lighting fittings installed in navigation bridge are to comply with the requirements of Pt 6, Ch 1, Sec 10 and KS C IEC 60092-306 as well as this guidance.


3102. Data to be submitted

The manufacturer wishing to obtain the type approval of LED lighting fittings is to submit the data required in Ch 3, Sec 3, 102. 3 to the Society.


3103. Type test

Type tests are to be carried out in accordance with Table 3.31.1 and supplementary tests may be required where deemed necessary by the Society. Type tests may be partly or wholly omitted, sub- ject to the approval by the Society, in cases where the manufacturer submits the test reports issued by an authorized test laboratory in accordance with the standard approved by the Society.


Table 3.31.1 Type test items


No.

Item

Test method

Remark

1

Visual inspection

No. 1


Table 3.23.1

of Ch 3, Sec 23

-

2

Performance Test

No. 2

-

3

Electrical power supply failure test

No. 3

-

4

Electrical power supply variation test

No. 4

-

5

Dry heat test

No. 6

-

6

Damp heat test

No. 7

-

7

Vibration test

No. 8

-

8

Insulation resistance test

No. 10

-


9

High voltage test


No. 11


-

10

Cold test

No. 12

-


11


EMC tests

No. 14 ~

21


-


12

Flame resistance test


No. 22


-


13


Salt mist test


No. 13

for deck

LED

lightings

installed

in

open

14

Mechanical strength test

(KS C) IEC 60092-306

-

15

Temperature rising test

(KS C) IEC 60092-306

-


16


IP test


(KS C) IEC 60529

Please refer to Pt 6, Ch 1, Table

6.1.6 regarding the required IP grade


17


Explosion-Proof test


(KS C) IEC 60079 Series

for LED lightings installed in hazard- ous areas


Guidance for Approval of Manufacturing Process and Type Approval, Etc. 2015 211