Iranian Classification Society Rules

< Previous | Contents | Next >

Section 1 General


101. Application


1. In application to 101, 2 of the Rules, it shall be applied to HSC code as follows,

(1) When one generator given in HSC Code 12.2.2 is failure, the electric from other generator shall is supplied to electrical equipment as follows,

(A) Essential auxiliaries related to the propulsion of the ships and safety of lives and ships

(refer to Pt 5, Ch 1, 102, 1 of Guidance for the Classification of Steel Ships. how- ever, except not pertaining to components of main propulsion system such as thrust, wind- lass, mooring winch, provision refrigerator)

(B) Lifting

(C) Launching devices for survival craft

(D) Emergency fire pump

(E) Open and close devices of watertight door

(F) Automatic sprinkler devices

(G) Draught fan

(H) Navigation aids

(I) Inboard lighting equipment

(J) Radio installations

(K) Air-conditioning heater

(L) Sanitary pump

(M) Potable water pump and evaporator

(N) Sewage treatment plant

(O) Cooking equipment (ranges, electric cooking utensils, etc.)

(2) In application to (1) above, for a ship restricted in coastal service (registered with service re- striction notations of equipment "C" or "S") and a passenger ship registered with service re- striction notations of equipment "S", the electrical equipments shall be supplied with the require- ments of (1), (A) to (1), (J) above.

(3) In accordance with the requirement of HSC Code

12.6.4.2, for all electric cables and wiring re-

quired not to impair their original flame-retarding properties, they shall be complied with Pt 6,

Ch 1, 404, 3 of Rules for the Classification

of Steel Ships to protect against fire, how-

ever, except ships not engaged on international voyages.