< Previous | Contents | Next >

Section 4 Monitoring Equipment


401. Monitoring Equipment


1. The control platform of the submersible is to be fitted with indicating instruments for monitoring at least the following environmental conditions inside the vehicle:

(1) Pressure

(2) Temperature

(3) Humidity

(4) Oxygen partial pressure

(5) CO2 partial pressure

(6) Pressure of connected breathing gas containers/bottles

(7) Outlet pressure of pressure reducing valves

2. The readings of the pressure gauges are to be accurate to at least 1 % of the complete indicating range. The use of mercury pressure gauges and thermometers is not permitted.


3. Each space should be provided with facilities for measuring the room temperature and the

Æ ĀË partial pressures.

4. A permanent gauge and a standby indicator are to be provided for monitoring both the

Æ ĀË partial pressure. Test tubes may be recognized as standby indicators.


ĀË and


ĀË and

5. The system for the analysis of oxygen is to have a minimum indicating accuracy of 0.015 bar oxy- gen partial pressure.


6. The CO2 analysis system is to have a minimum indicating accuracy of 0.001 bar Æ ĀË partial pressure.


7. A system of analysis is to

ÆĀ Ħ ÀĀĦ ÀĀ Ż and hydrocarbons.


be provided for determining atmospheric impurities Test tubes may be approved for this purpose.


such as